Nederlands English 

Correct sizing of the aeration system depends on the amount of oxygen required, on the sludge characteristics, on the 

process type and on the tank size.


OSSI-MIX:

Ability to adjust oxygen transfer; SOTR 11-135 kgO2 / hour (6m hydraulic head).


Arial-Jet (AJ):

Average power for installation in rectangular or round tanks 30-55 W / m. SOTR 1-70 kgO2 / hour

(6m hydraulic head).

Arial-Jet with extended channels (AJ / L):

Average power for installation in rectangular or round tanks 25 - 45 W / m. SOTR 1-85 kgO2 / hour

(6m hydraulic head).


Ossi jet (OJ):

Average power for installation in rectangular or round tanks:> 30W / m
solids content <1%; > 60W / m solids content <3.5%
SOTR 1-45 kgO2 / hour (6m hydraulic head).